Home » Electric Actuated Valves » Explosion-Proof Electric Metal Hard Seal Wafer Butterfly Valve
Explosion-Proof Electric Metal Hard Seal Wafer Butterfly Valve
Explosion-Proof Electric Metal Hard Seal Wafer Butterfly Valve
Description
Explosion-proof Structure and Performance
The explosion-proof structure of HEX series products complies with the relevant provisions ofGB3836.1-2021″Explosive AtmospheresPartl:Equipment-General Requirements”and GB3836.2-2021″Explosive Atmospheres Part2 Equipment Protection by flameproof Enclosures ‘d'”,and adopts a whole machine explosion-proof structure.The explosion-proof shell composed of various explosion-proolcomponents ofthe product can withstand the explosion pressure generated by the explosive gas mixture inside the shell during anexplosion,and can prevent the explosion inside the shell from spreading to the surrounding explosive gas environment outside theshellln other words, when an explosion occurs inside the productit will not propapate to the outside ofthe shell and ignite the explosi-ve gas mixture outside the shell.
Explosion-proof grade
The explosion-proof rating of this product is: ExdIBT4 Where:Ex-explosion-proof marking; d-explosion-prooftype,indicating”flameproof”: -equipment category,indicating electrical equip.ment for explosive gasenvironments otherthan coal mines:B-explosion level,which determines the dimensions(width and gap)of the explosion-proof joint surfaces ofthe actuator!T4-temperature class,indicating the maximum surface temperature allowed for the actuator is 135°c.In Appendix B of GB3836,1-2021,detailed levels and temperature classes of combustible gases and vapors are listedUsers may refer to it if necessary.Soecial attention:The tvpe and group of explosive substances surrounding the location where the product is used must be consistentwith the explosion-proof medium allowed by the product,otherwise,the explosion-proof effect cannot be achieved.
Precautions for use
Pay attention to the prompts on the warning labels.t is strictly prohibited to open any cover while live in the presence offlammable
and explosive gases (i.e.,opening the explosion-proof chamber ofthe product).The explosion-proof glass is pat of the explosion-proof structure and should not be disassembled or impacted with hard objectsduring use.When any explosion-proof parts of the product are damaged,they should be replace dimmediately.Before qualified partsare installed,the product should not be operated electrically.
The product nameplate and warning labels must not be torn off or lost,and the text on them should remain clear.
Explosion-proof Structural Diagram

| Serial No. | Name | Quantity | Material |
| 1 | Housing | 1 | ADC12 |
| 2 | Motor cover | 1 | ADC12 |
| 3 | Motor rotor shaft | 1 | 40Cr |
| 4 | Side cover | 1 | ADC12 |
| 5 | Rear cover | 1 | ADC12 |
| 6 | Explosion-proof plug | 1 | Brass plated with nickel |
| 7 | Explosion-proof Glass | 1 | |
| 8 | Explosion-proof lens cap | 1 | 304 |
| 9 | Top Cover | 1 | ADC12 |
| 10 | O-ring | 1 | Nitrile rubber |

| Model Power Supply/ParameterPerformance | HEX110 | HEX116 | ||||||
| DC24V | AC24V | AC380V | AC220V | DC24V | AC24V | AC380V | AC220V | |
| Motor power | 20W | 25W | ||||||
| Rated current | 1.5A | 2.12A | 0.22A | 0.35A | 1.95A | 2.52A | 0.25A | 0.4A |
| Standard Time/Torque | 12S/100Nm | 30S/100Nm | 12S/160Nm | 30S/160Nm | ||||
| Optional Time/Torque | 55S/50Nm | 15S/50Nm | 15S/50Nm 60S/100Nm | 6S/80Nm | 15S/80Nm | 15S/80Nm 60S/160Nm | ||
| Rotation Angle Range | 0~90°adjustable | |||||||
| Optional Control Circuit | Type AVB/C/D/E/FIMK/MT | |||||||
| Total Weight | 6.5kg | 6.7kg | ||||||
| Insulation resistance | AC24V:100M0/250VDC AC110V/AC220V/AC380V/100MQ/500VDC | |||||||
| Voltage Resistance Level | AC24V:500VAC 1 minute,AC110VIAC220V:1500V AC 1 minute.AC380V:1800VAC1 minute | |||||||
| Protection Level | IP65(Special custom IP67/P68) | |||||||
| Explosion-proof grade | Exd II BT4 | |||||||
| Mounting method | Installation at any angle of 360° | |||||||
| Electrical interface | 2-M20 explosion-proof plugs,users should install corresponding explosion-proof cable connectorsaccording to the selected cable when in use | |||||||
| Ambient temperature | -20℃+60℃ | |||||||
| Optional Features | Over-torque protection, dehumidification heater | Over-torque protection,dehumidification heater | ||||||

| Model Power Supply/ParameterPerformance | HEX120 | HEX140 | HEX160 | |||||||||
| DC24V | AC24V | AC380V | AC220V | DC24V | AC24V | AC380V | AC220V | DC24V | AC24V | AC380V | AC220V | |
| Motor power | 40W | 40W | 70W | 40W | 70W | 90W | ||||||
| Rated current | 3.5A | 3.03A | 0.3A | 0.5A | 5.2A | 3.6A | 0.4A | 0.55A | 6.04A | 6.8A | 0.29A | 0.67A |
| Standard Time/Torque | 12S/20ONm | 30S/200Nm | 12S/400Nm | 30S/400Nm | 15S/60ONm | 45S/600Nm | ||||||
| Optional Time/Torque | 6S/100Nm | 15S/200Nm | 15S/200Nm 60S/200Nm | 6S/200Nm | 15S/200Nm | 15S/200Nm 60S/200Nm | ||||||
| Rotation Angle Range | 0~90°adjustable | |||||||||||
| Optional Control Circuit | Type AVB/C/D/E/FIMK/MT | |||||||||||
| Total Weight | 9.2kg | 9.3kg | 9.5kg | |||||||||
| Insulation resistance | AC24V:100M0/250VDC AC110V/AC220V/AC380V 100Ω/500VDC | |||||||||||
| Voltage Resistance Level | AC24V:500V AC 1min,AC110V/AC220V: 1500VAC 1min,AC380V:1800VAC 1 min | |||||||||||
| Protection Level | IP65(Special custom IP67/P68) | |||||||||||
| Explosion-proof grade | Exd II BT4(Exd II CT6) | |||||||||||
| Mounting method | Installation at any angle of 360° | |||||||||||
| Electrical interface | 2-M20 explosion-proof plugs,users should install corresponding explosion-proof cable connectorsaccording to the selected cable when in use | |||||||||||
| Ambient temperature | -20℃+60℃ | |||||||||||
| Optional Features | Over-torque protection, dehumidification heater | |||||||||||

| Model Power Supply/ParameterPerformance | HEX1100 | HEX1200 | ||||
| DC24V | AC24V | AC220V | AC380V | DC220V | AC380V | |
| Motor power | 120W | 120W | 150W | |||
| Rated current | 9.5A | 9A | 0.94A | 0.44A | 1.2A | 0.65A |
| Standard Time/Torque | 25S/1000Nm | 60S/1000Nm | 60S/2000Nm | |||
| Optional Time/Torque | / | |||||
| Rotation Angle Range | 0-90°adjustable | |||||
| Optional Control Circuit | Type AVB/C/D/E/F/MK/MT | |||||
| Total Weight | 12.8kg | 13kg | ||||
| Insulation resistance | 100MQ1500VDC(AC110VAC220V/AC380V | |||||
| Voltage Resistance Level | 1500VAC/1min(AC110VAC220V/AC380V | |||||
| Protection Level | IP65 (Special custom IP67/IP68) | |||||
| Explosion-proof grade | Exd II BT4 | |||||
| Mounting method | Installation at any angle of 360° | |||||
| Electrical interface | 2-M20 explosion-proof plugs,users should install corresponding explosion-proof cable connectorsaccording to the selected cable when in use | |||||
| Ambient temperature | -20℃~+60℃(other temperatures can be customized) | |||||
| Optional Features | Dehumidifying Heater,Overheat Fault Signal | |||||