Home » Electric Actuators » Explosion Proof Electric Actuator » Explosion-Proof Quarter-Turn Electric Actuator
Explosion-Proof Quarter-Turn Electric Actuator
Explosion-Proof Quarter-Turn Electric Actuator
- Torque Rotational Moment: 50 Nm ~ 2000 Nm
- Motor Power: 220VAC, 24V AC/DC 1Ph, 380℃ V AC 3Ph. 50/60 Hz± 10%
- Temperature: -20℃ – 70℃
- Flanged Connection: ISO 5211 or DIN 3337 Standard
- Control: On-off or Proportional Control
- Accessories: Proportional Card, limit switch can be added, 4-20 mA Output Smart Type Electric Actuators.
- Protection Class: Weatherproof – lP67; Explosion Proof – Exd lB T4
- Application: BallValves, Butterfly Valves, Dampers
Description
Explosion-proof Structure and Performance
Discover the robust performance of our Explosion-Proof Quarter-Turn Electric Actuator, featuring a high-level protection rating of ExdIBT4. This actuator is designed for reliable operation in hazardous environments, ensuring safety and efficiency. With a wide range of torque capabilities and compatibility with various valve types, it’s the ideal solution for demanding industrial applications
The explosion-proof structure of HEX series products complies with the relevant provisions of GB3836.1-2021″Explosive AtmospheresPart1:Equipment-General Requirements”and GB3836.2-2021″Explosive Atmospheres Part2 Equipment Protection by flameproof Enclosures ‘d”.and adopts a whole machine explosion-proof structure. The explosion-proof shell composed of various explosion-proolcomponents of the product can withstand the explosion pressure generated by the explosive gas mixture inside the shell during anexplosion,and can prevent the explosion inside the shel from spreading to the surrounding explosive gas environment outside theshel.lin other words, when an explosion occurs inside the product, it will not propagate to the outside ofthe shell and ignite the explosi-ve gas mixture outside the shell.
Explosion-proof grade
The explosion-proof rating of this product is: ExdIBT4
Where: Ex-explosion-proof marking; d-explosion-prooftype,i ndicating”flameproof”: -equipment category, indicating electrical equip.ment for explosive gas environments other than coal mines:B-explosion level, which determines the dimensions(width and gapof the explosion-proof joint surfaces of the actuator. T4-temperature class,indicating the maximum surface temperature allowed for the actuator is 135°C. In Appendix B of GB3836.1-2021, detailed levels and temperature classes of combustible gases and vapors are listed
Users may refer to it if necessary.
Special attention: The type and group of explosive substances surrounding the location where the product is used must be consistentwith the explosion-proof medium allowed by the product, otherwise, the explosion-proof effect cannot be achieved.
Precautions for use
Pay attention to the prompts on the warning labels. It is strictly prohibited to open any cover while live in the presence of flammableand explosive gases ( i.e.,opening the explosion-proof chamber of the product).
The explosion-proof glass is part of the explosion-proof structure and should not be disassembled or impacted with hard objects during use. When any explosion-proof parts of the product are damaged, they should be replace dimmediately. Before qualified parts are installed, the product should not be operated electrically. The product nameplate and warning labels must not be torn off or lost,and the text on them should remain clear.
Parts Material

| Serial No. | Name | Quantity | Material |
| 1 | Motor cover | 1 | ADC12 |
| 2 | Motor rotor shaft | 1 | 40Cr |
| 3 | Cabinet | 1 | ADC12 |
| 4 | Explosion-proof plug | 2 | nickel-plated brass |
| 5 | O-ring | 1 | Nitrile rubber |
| 6 | Control cover | 1 | ADC12 |
| 7 | Electrical cover | 2 | ADC12 |
| 8 | O-ring | 1 | Nitrile rubber |
| 9 | Explosion-proof lenses | 2 | |
| 10 | Output shaft | 1 | 40Cr nickel plating |

| Model Power Supply/ParameterPerformance | HEX110 | HEX116 | ||||||
| DC24V | AC24V | AC380V | AC220V | DC24V | AC24V | AC380V | AC220V | |
| Motor power | 20W | 25W | ||||||
| Rated current | 1.5A | 2.12A | 0.22A | 0.35A | 1.95A | 2.52A | 0.25A | 0.4A |
| Standard Time/Torque | 12S/10ONm | 30S/100Nm | 12S/160Nm | 30S/160Nm | ||||
| Optional Time/Torque | 5S/50Nm | 15S/50Nm | 15S/50Nm 60S/100Nm | 6S/80Nm | 15S/80Nm | 15S/80Nm 60S/160Nm | ||
| Rotation Angle Range | 0~90°adjustable | |||||||
| Optional Control Circuit | Type AVB/C/D/E/F/MK/MT | |||||||
| Total Weight | 6.5kg | 6.7kg | ||||||
| Insulation resistance | AC24V:100M0/250VDC AC110V/AC220V/AC380V:100Ω/500VDC | |||||||
| Voltage Resistance Level | AC24V:500VAC 1min, AC110V/AC220V:1500VAC 1min,AC380V:1800VAC 1 min | |||||||
| Protection Level | IP65(Special custom IP67/P68) | |||||||
| Explosion-proof grade | Exd II BT4 | |||||||
| Mounting method | Installation at any angle of 360° | |||||||
| Electrical interface | 2-M20 explosion-proof plugs,users should install corresponding explosion-proof cable connectorsaccording to the selected cable when in use | |||||||
| Ambient temperature | -20℃+60℃ | |||||||
| Optional Features | Over-torque protection, dehumidification heater | |||||||

| Model Power Supply/ParameterPerformance | HEX120 | HEX140 | HEX160 | |||||||||
| DC24V | AC24V | AC380V | AC220V | DC24V | AC24V | AC380V | AC220V | DC24V | AC24V | AC380V | AC220V | |
| Motor power | 40W | 40W | 70W | 40W | 70W | 90W | ||||||
| Rated current | 3.5A | 3.03A | 0.3A | 0.5A | 5.2A | 3.6A | 0.4A | 0.55A | 6.04A | 6.8A | 0.29A | 0.67A |
| Standard Time/Torque | 12S/20ONm | 30S/200Nm | 12S/400Nm | 30S/400Nm | 15S/60ONm | 45S/600Nm | ||||||
| Optional Time/Torque | 6S/100Nm | 15S/200Nm | 15S/200Nm 60S/200Nm | 6S/200Nm | 15S/200Nm | 15S/200Nm 60S/200Nm | ||||||
| Rotation Angle Range | 0~90°adjustable | |||||||||||
| Optional Control Circuit | Type AVB/C/D/E/FIMK/MT | |||||||||||
| Total Weight | 9.2kg | 9.3kg | 9.5kg | |||||||||
| Insulation resistance | AC24V:100M0/250VDC AC110V/AC220V/AC380V 100Ω/500VDC | |||||||||||
| Voltage Resistance Level | AC24V:500V AC 1min,AC110V/AC220V: 1500VAC 1min,AC380V:1800VAC 1 min | |||||||||||
| Protection Level | IP65(Special custom IP67/P68) | |||||||||||
| Explosion-proof grade | Exd II BT4(Exd II CT6) | |||||||||||
| Mounting method | Installation at any angle of 360° | |||||||||||
| Electrical interface | 2-M20 explosion-proof plugs,users should install corresponding explosion-proof cable connectorsaccording to the selected cable when in use | |||||||||||
| Ambient temperature | -20℃+60℃ | |||||||||||
| Optional Features | Over-torque protection, dehumidification heater | |||||||||||

| Model Power Supply/ParameterPerformance | HEX1100 | HEX1200 | ||||
| DC24V | AC24V | AC220V | AC380V | DC220V | AC380V | |
| Motor power | 120W | 120W | 150W | |||
| Rated current | 9.5A | 9A | 0.94A | 0.44A | 1.2A | 0.65A |
| Standard Time/Torque | 25S/1000Nm | 60S/1000Nm | 60S/2000Nm | |||
| Optional Time/Torque | / | |||||
| Rotation Angle Range | 0-90°adjustable | |||||
| Optional Control Circuit | Type AVB/C/D/E/F/MK/MT | |||||
| Total Weight | 12.8kg | 13kg | ||||
| Insulation resistance | 100MQ1500VDC(AC110VAC220V/AC380V | |||||
| Voltage Resistance Level | 1500VAC/1min(AC110VAC220V/AC380V | |||||
| Protection Level | IP65 (Special custom IP67/IP68) | |||||
| Explosion-proof grade | Exd II BT4 | |||||
| Mounting method | Installation at any angle of 360° | |||||
| Electrical interface | 2-M20 explosion-proof plugs,users should install corresponding explosion-proof cable connectorsaccording to the selected cable when in use | |||||
| Ambient temperature | -20℃~+60℃(other temperatures can be customized) | |||||
| Optional Features | Dehumidifying Heater,Overheat Fault Signal | |||||