- Torque Rotational Moment: 30 Nm ~ 2000 Nm
- Motor Power: 220VAC, 24V AC/DC 1Ph, 380℃ VAC 3Ph. 50/60 Hz± 10%
- Temperature: -20℃ – 70℃
- Flanged Connection: ISO 5211 or DIN 3337 Standard
- Control: On-off or Proportional Control
- Accessories: Proportional Card, limit switch can be added, 4-20 mA Output Smart Type Electric Actuators.
- Protection Class: Weatherproof – lP67
- Application: BallValves, Butterfly Valves, Dampers
- Optional: Weatherproof – IP68
Description
Our Core Engineering Overview
We customized the HEA(A) Series compact electric actuator with LCD for the high-end digital upgrades of your packaged equipment and DCS bus networking. This model perfectly fuses our minimal physical footprint with advanced digital human-machine interaction. We integrated an external micro-LCD smart control box that supports non-intrusive, cover-free onsite control and parameter calibration, fundamentally resolving your pain points of cumbersome commissioning in hazardous isolation zones.

Features & Benefits
Technical Specifications & Material Breakdown
- Smart Control Unit: We equip this model with an external compact microprocessor control box, featuring a Local/Remote selector switch and local Open/Stop/Close command knobs.
- Digital Interface: We provide a high-contrast digital display screen that delivers real-time, onsite readouts of your actuator’s opening percentage, operational status, and self-diagnostic fault codes.
- Heavy-Duty Capabilities: While our compact line handles tight spaces seamlessly, our standard intelligent configurations can deliver up to 5,000 Nm of torque for your massive industrial mainlines.
Our Available Upgrades
We highly recommend selecting our optional anti-condensation space heater to protect the sensitive microprocessors from moisture, alongside an optional Power Failure Self Reset module to drive your valves to a safe position during unexpected plant blackouts.
Industrial Standards & Safety Compliance
Since opening an electrical enclosure in an explosive atmosphere is strictly prohibited, we developed this non-intrusive design to ensure your factory-tested IP67 seals remain completely uncompromised. The product strictly holds ATEX, CNEX, and the highest level of SIL3 safety integrity certifications.
Parts Material
![]() | No. | Qty | Part name | No. | Qty | Part name |
| 1 | 1 | Indication window hood | 36 | 1 | Fixing base(ISO5211) | |
| 2 | 4 | Intemal hexangular fillister head screw | 37 | 4 | Internal hexangular fillister head screw | |
| 3 | 1 | Viewing glass | 38 | 1 | Bearing | |
| 4 | 1 | O-ring | 39 | 1 | Worm screw | |
| 5 | 1 | Electric fitting: top cap | 40 | 1 | flat key | |
| 6 | 4 | Anti-break off hex type socket screw | 41 | 1 | Bearing | |
| 7 | 1 | O-ring | 42 | 1 | locknut | |
| 8 | 1 | Cross bolt | 43 | 1 | Gear on womm | |
| 9 | 1 | Dial | 44 | 1 | Axis shield ring | |
| 10 | 4 | Cross bolt (component) | 45 | 1 | O-ring | |
| 11 | 4 | Travel switch | 46 | 1 | oil seal | |
| 12 | 2 | Insulation plate guard | 47 | 6 | Anti-break off hex type socket screw | |
| 13 | 2 | Insulation pad | 48 | 1 | Cross bolt (component) | |
| 14 | 4 | Hex type socket holding screw | 49 | 1 | Dustproof end plug | |
| 15 | 2 | Stroke dog | 50 | 1 | Electric fitting: front cap | |
| 16 | 4 | Cross bolt (component) | 51 | 1 | Electric fitting: speed-down case 1 | |
| 17 | 1 | Electric fitting: inner cap | 52 | 3 | Bearing | |
| 18 | 1 | Cross bolt (component) | 53 | 3 | Electric fitting. reduction gear component | |
| 19 | 1 | Electric capacitor | 54 | 3 | Bearing | |
| 20 | 1 | Electric ftting: case body | 55 | 1 | Electric fitting: speed-down case body | |
| 21 | 2 | Limit bolt | 56 | 5 | Cross bolt (component) | |
| 22 | 2 | Hexagonal nuts | 57 | 1 | Cross bolt (component) | |
| 23 | 1 | Waterproof cable joint | 58 | 1 | Dial needle | |
| 24 | 1 | Connecting terminals | 59 | 1 | Pointer rod | |
| 25 | 2 | Cross bolt | 60 | 1 | Rubber end plug | |
| 26 | 1 | Cross bolt | 61 | 1 | Wavy spring washer | |
| 27 | 1 | O-ring | 62 | 1 | Bearing | |
| 28 | 4 | Anti-break off hex type socket screw | 63 | 1 | Insulating division board | |
| 29 | 1 | Electric fitting: lead-in cap | 64 | 1 | Electromotor stator | |
| 30 | 1 | Bearing | 65 | 1 | Electromotor rotor | |
| 31 | 1 | Worm wheel | 66 | 1 | Bearing | |
| 32 | 1 | Bearing | 67 | 1 | Insulating division board | |
| 33 | 1 | oil seal | 68 | 1 | Electromotor cap | |
| 34 | 1 | Hex type socket holding screw | 69 | 1 | oil seal | |
| 35 | 1 | Connecting bushing (IS05211) | 70 | 1 | Oil seal stop plate | |
| 71 | 2 | Cross bolt (component) |
| Model | HEA005A | ||
| Power Supply | DC24V | AC110V | AC220V |
| Output Torque | 50NM | 50NM | 50NM |
| Motion Times(s) | 20 | 20 | 20 |
| Scope of Rotary Angle (°) | 0-360° | 0-360° | 0-360° |
| Motor Power(w) | 13 | 10 | 10 |
| Rated Current(A) | 1.28 | 0.24 | 0.18 |
| Machine Weight(kg) | 2.2 | 2.2 | 2.2 |
| Insutation Resistance(MΩ) | DC24V:100MΩ/250VDC AC110V/220V 380V:100MΩ/500VDC | ||
| Voltage Resistance Rating | DC24V:500VAC; AC110V/220V:1500VAC; AC380V:1800VAC(1 Minute) | ||
| Protection Level | IP66 | ||
| Installation Position | Rotary degree :360° | ||
| Electrial Connection | Each one G1/2 water-proof cable connectors, electric power lines, signal lines | ||
| Environment Temperature | -30°~+60° | ||
| Control Circuit Options | Standard type:Limit position switch A type: with mid-position switch B type: with potentiometer C type: with potentiometer and mid-positione switch. D type: with servo controller(Regulatory) | ||
| Optional Function | Over torque protectors Dehumidify heater | ||
| Model | HEA010A | |||
| Power Supply | DC24V | AC110V | AC220V | AC380V |
| Output Torque | 100NM | 100NM | 100NM | 100NM |
| Motion Times(s) | 30/60 | 30/60 | 30/60 | 30/60 |
| Scope of Rotary Angle (°) | 0-360° | 0-360° | 0-360° | 0-360° |
| Motor Power(w) | 25 | 25 | 25 | 25 |
| Rated Current(A) | 2.03 | 0.57 | 0.35 | 0.1 |
| Machine Weight(kg) | 4 | 4 | 4 | 4 |
| Insutation Resistance(MΩ) | DC24V:100MΩ/250VDC AC110V/220V 380V:100MΩ/500VDC | |||
| Voltage Resistance Rating | DC24V:500VAC; AC110V/220V:1500VAC; AC380V:1800VAC(1 Minute) | |||
| Protection Level | IP66 | |||
| Installation Position | Rotary degree :360° | |||
| Electrial Connection | Each one G1/2 water-proof cable connectors, electric power lines, signal lines | |||
| Environment Temperature | -30°~+60° | |||
| Control Circuit Options | Standard type: Limit position switch A type: with mid-position switch B type: with potentiometer C type: with potentiometer and mid-positione switch. D type: with servo controller(Regulatory) | |||
| Optional Function | Over torque protectors Dehumidify heater | |||
| Model | HEA020A | HEA040A | HEA060A | HEA080A |
| Output Torque | 20kgf·m | 40kgf·m | 60kgf·m | 80kgf·m |
| Motion Times(s) | 15/30/45 | 30/45 | 30/45 | 60 |
| Scope of Rotary Angle (°) | 0-90° | 0-90° | 0-90° | 0-90° |
| Motor Power(w) | 40/30 | 90/60 | 100 | 100 |
| Rated Current(A) | 0.37/0.25 | 0.69/0.51 | 0.85 | 0.85 |
| Machine Weight(kg) | 11 | 11 | 11.3 | 11.3 |
| Power Supply (v) | DC24V AC110V AC220V±10% 50HZ/60HZ AC380V | |||
| Motor Protection | Built-in thermal protection | |||
| Insutation Resistance(MΩ) | 100MΩ/500VDC | |||
| Voltage Resistance Rating | 1500VAC (1 Minute) | |||
| Manual Operation | It comes with stainless steel handles | |||
| Protection Level | IP66 | |||
| Installation Position | Rotary degree :360° | |||
| Electrial Connection | Each one G1/2 water-proof cable connectors, electric power lines, signal lines | |||
| Limit Element | Limit switch,Mechanical strike block | |||
| Environment Temperature | -20°~+60° | |||
| Control Circuit Options | Standard type:Limit position switch A type:with mid-position switch B type:with potentiometer C type:with potentiometer and mid-positione switch. D type:with servo controller(Regulatory) | |||
Purchase Guide
| Feature / Metric | On-Off Type (Standard) | Integrated Modulating (Intelligent) | External Modulating (Potentiometer) |
| Control Signal Input | None (AC/DC Power Only) | 4-20mA / 0-10V DC | None (Remote Analog Box) |
| Position Feedback | 2 × SPDT Limit Switches | 4-20mA Output / LCD | High-Precision Potentiometer |
| Control Board Location | No Board Required | Built-in (Inside Actuator) | External (In Control Room) |
| Max Working Temp | Standard (-20°C to 60°C) | Standard (-20°C to 60°C) | High Temp Isolation Approved |
| Vibration Resistance | Standard | Vulnerable (Electronics Risk) | Extreme Shock-Resistant |
| Field Wiring Footprint | Standard | Reduced by 50% (No Local Panel) | Centralized Multi-Node Routing |
| Procurement Advantage | Lowest Cost / Max Profit Margin | Fastest Commissioning Time | Lowest Node Replacement Cost |
FAQ
Q1: What distinguishes the external display modulating type from the internal type?
The external display type features a visible screen on the actuator housing, allowing operators to read position feedback and adjust parameters directly on the unit without additional tools or external devices.
Q2: What parameters can be set via the external display?
Electric actuator with LCD typical on-screen settings include open/close position calibration, signal range configuration, running speed, and fault status. Exact menu options depend on the control module version — please request the relevant manual for full details.
Q3: What input control signal does this type accept?
Standard is 4–20mA. 0–10V and other signal ranges may be available depending on the control module selected. Confirm at time of order.
Q4: Does the external display type provide position feedback output?
Yes. The integrated potentiometer or control module provides analog feedback output, typically 4–20mA, for SCADA or PLC integration.
Q5: Is the external display type field-configurable without opening the housing?
Yes. The external screen and buttons allow parameter adjustment without opening the enclosure, preserving IP67 integrity during configuration.
Q6: Can I switch an external display modulating unit back to on/off control if requirements change?
On the external display modulating type electric actuator with LCD, the actuator can be configured to operate as a simple open/close unit via the control module settings, without requiring hardware changes.
Q7: Is AC24V available for the external display modulating type?
Yes, AC24V is available on request across the HEA(A) line, including the external display modulating variant.