Modulating Type Electric Actuator

Modulating Type Electric Actuator

Item Number: HEA Series
  • Torque Rotational Moment: 30 Nm ~ 2000 Nm
  • Motor Power: 220 V AC, 24 V AC/DC 1Ph, 380V AC 3Ph. 50/60 Hz ± 10%
  • Temperature: -20°C – 70°C
  • Flanged Connection: ISO 5211 or DIN 3337 Standard
  • Control: On-off or Proportional Control
  • Accessories: Proportional Card, limit switch can be added, 4-20mA Output; Smart Type Electric Actuators.
  • Protection Class: Weather proof- IP67
  • Application: Ball Valves, Butterfly Valves, Dampers
Quote Now


    Electric actuator production line

    Quick Help: Contact one of our experts and we'll get back to you in 24 hours!

    Get Free Catalog


      Electric actuator production line

      Quick Help: Attachments will be downloaded automatically after form submission!

      LinkedIn
      Instagram
      YouTube

      Description

      The HEA Series quarter turn modulating type electric actuator is a purpose-built proportional electric actuator engineered for precise electric actuator flow control across demanding industrial networks. Balancing a standard physical footprint with high-precision analog signal processing, the Proportional Control Unit (PCU) is integrated securely within a standard hard-anodized aluminum alloy enclosure. Operating as a fully sealed IP67 modulating type electric actuator, this architecture provides optimal heat dissipation for internal electronics while maintaining high-frequency modulating accuracy. It is the definitive choice for continuous flow regulation requiring reliable, closed-loop feedback, and serves as an ideal driver for a modulating electric actuator butterfly valve assembly without the complexity of customized external cabinets.

      HEA Series Electric Actuator Control Type Comparison-Modulating (Built-in)

      Technical Specifications & Signal Integration

      • Integrated Servo Module: The PCU is built directly into the unit, keeping all signal processing circuits strictly shielded from external plant environments.
      • Signal Compatibility: The main board operates natively as a 4-20mA electric actuator and 0-10V electric actuator. It supports multi-protocol analog inputs and outputs for direct integration with your electric actuator DCS control or electric actuator PLC control architecture. For digital networks, the unit can be specified as a Modbus electric actuator or RS485 electric actuator.
      • Dynamic Feedback Components: Equipped with a high-precision Position Feedback Potentiometer (1kΩ-10KΩ), providing real-time, zero-hysteresis valve position tracking via a dedicated electric actuator 4-20mA feedback output.

      Environmental Upgrades & Industrial Procurement

      For high-humidity installations or plants handling severe thermal medium cycles, an internal 5W 10K dehumidification space heater is available. This prevents internal moisture accumulation and electrochemical corrosion on the integrated modulating PCB. For industrial procurement and global project schedules, standard manufacturing lead time is 15 to 25 days, backed by a verified monthly production capacity.

      Industrial Standards & Safety Compliance

      Internal proportional tracking adheres to strict linear accuracy testing protocols. For high-frequency modulating applications in volatile processing environments, the unit is fully certified under ATEX, CNEX, and SIL3 safety integrity frameworks, ensuring maximum resistance to extreme electromagnetic interference.

      Features

      • Integrated Servo Module: We build the PCU directly into the unit, keeping all signal processing circuits completely shielded from your plant’s external environment.
      • Signal Compatibility: Our boards support your multi-protocol analog input and output signals (4…20mA, 1…5 VDC, 1…10VDC) for direct integration with your DCS or PLC automation architecture.
      • Our Available Upgrades: If your outdoor installations face severe day-to-night temperature fluctuations or high humidity (up to 90% RH), we highly recommend our optional 5W 10K internal space heater (dehumidification heater). This device maintains a stable micro-thermal environment, completely eliminating internal condensation to protect your electronics from short circuits.

      Our Available Upgrades

      For your high-humidity installations or plants handling severe thermal medium cycles, we offer an internal 5W 10K dehumidification space heater as an optional upgrade. It eliminates internal moisture accumulation, preventing electrochemical corrosion on your integrated modulating PCB.

      Industrial Standards & Safety Compliance

      We ensure our internal proportional tracking adheres to strict linear accuracy testing protocols. For your high-frequency modulating applications in volatile processing environments, we fully certify the unit under ATEX, CNEX, and SIL3 safety integrity frameworks, ensuring it resists extreme electromagnetic interference.

      Performance Features

      Fuction:On/off or modulating
      Material
      Housing:Aluminum alloy,epoxy powder coated
      Gear:Steel/aluminum bronze
      Screws:Stainless steel
      Indicator Cover:Polycarbonated
      Shaft/Adaptor:Alloy steel
      Seal:NBR
      Lubrication:Aluminum based grease
      Technical Date
      Power Supply:24VDC,110VAC,220VAC
      Motor:Squirrel cage asynchronous motor
      Limit SwitchSPDT,250VAC 10A,each for open and close positions
      Rotation:90° (±10°)other rotation on request
      Manual Operation:Mechanical handle standard
      Conduit Entry:2 x M18
      Operating Temp:-20°C to + 70°C
      Ambient Humidity:Max.90%RH
      Vibration Tested:XYZ10g,0.2~34Hz,30 minutes
      Mounting:ISO5211
      Torque Output:30Nm to 1000Nm (2000Nm on request)
      Self-locking device:Self-locking by worm and worm gear

      Options Available

      Space Heater, 7 … 10W (110/220VAC)*
      Stall Protection, internal overheating protection, open @ 120oC / close @ 97oC (± 5oC)*
      Position Feedback Potentiometer (1K … 10K)*
      Position Feedback Sensor with Current output (4 … 20mA)*
      Proportional Control Unit for modulating control
      (input/output signal, 4 … 20mA, 1 … 5 VDC, 1 … 10VDC)*
      Field control unit
      (Local control open/stop/close switch, Local/remote control switch)*
      Power Failure Self Reset

      Standard & Technical datas

      IndicatorDome Type( Option: LED Light Inside)EnclosureWaterproof Level IP67,NEMA4 and 6
      Ambient Temp-20℃~+70℃Power SupplyAC110/220V 1PH±10% 50/60HZ.DC24V
      Limit Switches2 open/close+dry contact 2 open/closeTravel Angle90º±5°(Extension up to 270º)
      Manual OperationHex key (Option: Handwheel)Self LockingProvide self locking by worm gear
      Space Heater5W(110/230VAC,24VDC)Conduit entries2PF 1/2”(Option:M20x1.5,NPT1/2”)
      LubricationAluminum base grease(EP type)External CoatingDry powder, epoxy polyester
      Surface TreatmentAnodizingMaterialAluminum Alloy, Steel, Alloy Bronze

       

      Parts Materials

      HEA material

      NO.QtyPart nameNO.QtyPart name
      11Cross bolt (component)312Hexagonal nut
      21Dustproof end plug322Waterproof cable joint
      36Anti-break off hex type socket screw332O-ring
      41Oil seal342gasket
      51Electric fitting: front cap351Bearing
      61O-ring361Oil seal
      73Cross bolt (component)371Worm wheel
      83Cross bolt (component)381Electric fitting: inner cap
      91Electric fitting: speed-down case body391Bearing
      103Bearing404Cross bolt (component)
      113Electric fitting: reduction gear component411Stroke dog
      123Bearing421gasket
      131Electric fitting: speed-down case 1431Stroke dog
      141Axis shield ring441gasket
      153Cross bolt (component)451gasket
      161Gear on worm461gasket
      171Insulating division board471Cross bolt (component)
      181Locknut481Dial
      191Electromotor rotor491Cross bolt
      201Bearing501Connecting terminal
      211Flat key512Cross bolt
      221Worm screw521Electric capacitor
      231Electromotor stator531Viewing glass
      241Bearing541O-ring
      251Bearing551Electric fitting: top cap
      261Insulating division board564Anti-break off hex type socket screw
      271Electric fitting: case body571O-ring
      281Allen wrench581Indication window hood
      292Limit bolt594Internal hexangular fillister head screw
      301handle holder

      Technical Parameter and Specifications

      ModelMax OutputOperatingDrive Shaft(mm)MotorSingle-phsaeWeightFlange
      Torque (N.m)Time 90°(Sec.)(W)rated current(A)(kg)Size
      220VAC/24VDCSquareDeepRoundDeep220VAC/24VDC
      HEA00550N.m30/1511X1115.5Ø12.626100.25/2.24.1F05/F07
      14X1418
      HEA00880N.m30/1511X1115.5Ø15.7826100.25/2.24.1F05/F07
      14X1418
      HEA010100N.m30/1514X1418Ø15.7828150.35/3.55.1F05/F07
      17X1722.5Ø 18.95
      HEA015150N.m30/1514X1418Ø18.9528150.37/3.55.1F05/F07
      17X1722.5
      HEA020200N.m30/1522X2226Ø22.1345450.3/7.29.4F07/F10
      HEA040400N.m30/1522X2226Ø28.4845600.33/7.29.4F07/F10
      HEA060600N.m30/1527X2732.5Ø31.6545900.33/7.29.8F07/F10
      HEA080800N.m40/2027X2732.5Ø31.65451800.47/1115F10/F12
      HEA1001000N.m40/2027X2732.5Ø31.65451800.47/1115F10/F12
      HEA2002000N.m45/2227X2732.5Ø31.65451801.5/1515.3F10/F12

      Purchase Guide

      * The built-in modulating version accepts 4–20mA or 0–10V input and provides proportional position control. No external display or local buttons — signal-controlled only.

      Required parameters to place an order

      ParameterOptions / notes
      [Required] Model

      HEA003 – HEA200 (same range as on/off)

       

      Not sure? Contact us for selection support.

      [Required] Voltage24VDC · 110VAC · 220VAC · 380VAC · 415VAC
      [Required] Control signal input4–20mA or 0-10V
      [Required] Feedback output type

      4–20mA or 0-10V continuous position output

       

      Dry-contact open/close signals included as standard regardless.

      [Required] Quantity

      Optional — add to order notes if needed

      OptionNotes
      Modbus RTU (RS485)Bus control and monitoring; analog feedback remains active alongside
      Rotation angleDefault 90°; specify if 180° or 270°
      Space heaterSpecify voltage if required
      Seal materialNBR (default) or EPDM
      Low-temperature configSpecify minimum ambient temp if below -20°C
      Custom colorAny RAL code; no MOQ

       

      FAQ About HEA Internal Modulating Type Quarter-Turn Electric Actuator

      Q1: What control signal types are accepted?
      A1: As a standard 4-20mA valve actuator, it accepts 4–20mA current signals and 0–10V voltage signals. Please specify your required signal type during the specification phase.

      Q2: How does 4-20mA electric actuator work to determine valve position?
      A2: How does 4-20mA electric actuator work? The analog signal maps linearly to the mechanical stroke: 4mA = fully closed (0%), 8mA = 25% open, 12mA = 50% open, 16mA = 75% open, 20mA = fully open (100%). This allows straightforward integration with process controllers.

      Q3: What is the structural difference between a modulating vs on off electric actuator?
      A3: When evaluating a modulating vs on off electric actuator, on-off units only drive the valve to 0% or 100% limits. A modulating electric actuator utilizes a positioning PCU board to maintain any intermediate stroke position, which is mandatory for applications like electric actuator water treatment modulating or precise electric actuator HVAC proportional control.

      Q4: What position feedback outputs are available?
      A4: A built-in potentiometer provides continuous position sensing. You can specify an electric actuator 4-20mA feedback output or a 0-10V voltage output, functioning alongside standard open/close dry-contact signals.

      Q5: What is the rated service life of the internal gear train?
      A5: The mechanical and electrical assemblies meet a strict electric actuator 30000 cycle life rating, making the unit structurally sound for continuous modulating duty in heavy industrial process control.

      Q6: Does the actuator hold its position after a plant power failure?
      A6: Yes. The internal worm gear acts as a modulating actuator self locking mechanism, keeping the valve mechanically locked in its last position when power is lost. A Power Failure Self Reset function can restore the control position upon power resumption.

      Q7: What is the safe operating temperature range?
      A7: Standard operating range is -20°C to +70°C. Low-temperature configurations are available down to -70°C for LNG, cold-climate pipelines, and refrigerated storage pipelines.

      Q8: What specific safety and environmental certifications does it hold?
      A8: Certification claims are strictly maintained to ATEX, CNEX, and SIL3 compliance frameworks to meet the core safety requirements of petrochemical and chemical processing industries.

      Q9: Can it be ordered in custom RAL colors?
      A9: Yes. Any RAL color can be specified with no minimum order quantity. Delivery will extend slightly beyond our standard 15 to 25-day lead time due to custom industrial paint mixing.

      Related Products

      Related Posts

      Industrial Valve Selection The 4 Core Types

      Industrial Valve Selection: The 4 Core Types

      Focus on Producing Electric Globe Valves

      Electric Globe Valve: The Ultimate Engineering Guide for 2026

      Ball Valve Working Principle and Types

      Ball Valve Working Principle and Types: Structure, Function, and Uses

      Various Types of Ball Valves

      Ball Valve Types: The Ultimate Guide to Design, Features, and Applications