Modulating Type Electric Actuator
- Torque Rotational Moment: 30 Nm ~ 2000 Nm
- Motor Power: 220 V AC, 24 V AC/DC 1Ph, 380V AC 3Ph. 50/60 Hz ± 10%
- Temperature: -20°C – 70°C
- Flanged Connection: ISO 5211 or DIN 3337 Standard
- Control: On-off or Proportional Control
- Accessories: Proportional Card, limit switch can be added, 4-20mA Output; Smart Type Electric Actuators.
- Protection Class: Weather proof- IP67
- Application: Ball Valves, Butterfly Valves, Dampers
Description
The HEA Series quarter turn modulating type electric actuator is a purpose-built proportional electric actuator engineered for precise electric actuator flow control across demanding industrial networks. Balancing a standard physical footprint with high-precision analog signal processing, the Proportional Control Unit (PCU) is integrated securely within a standard hard-anodized aluminum alloy enclosure. Operating as a fully sealed IP67 modulating type electric actuator, this architecture provides optimal heat dissipation for internal electronics while maintaining high-frequency modulating accuracy. It is the definitive choice for continuous flow regulation requiring reliable, closed-loop feedback, and serves as an ideal driver for a modulating electric actuator butterfly valve assembly without the complexity of customized external cabinets.

Technical Specifications & Signal Integration
- Integrated Servo Module: The PCU is built directly into the unit, keeping all signal processing circuits strictly shielded from external plant environments.
- Signal Compatibility: The main board operates natively as a 4-20mA electric actuator and 0-10V electric actuator. It supports multi-protocol analog inputs and outputs for direct integration with your electric actuator DCS control or electric actuator PLC control architecture. For digital networks, the unit can be specified as a Modbus electric actuator or RS485 electric actuator.
- Dynamic Feedback Components: Equipped with a high-precision Position Feedback Potentiometer (1kΩ-10KΩ), providing real-time, zero-hysteresis valve position tracking via a dedicated electric actuator 4-20mA feedback output.
Environmental Upgrades & Industrial Procurement
For high-humidity installations or plants handling severe thermal medium cycles, an internal 5W 10K dehumidification space heater is available. This prevents internal moisture accumulation and electrochemical corrosion on the integrated modulating PCB. For industrial procurement and global project schedules, standard manufacturing lead time is 15 to 25 days, backed by a verified monthly production capacity.
Industrial Standards & Safety Compliance
Internal proportional tracking adheres to strict linear accuracy testing protocols. For high-frequency modulating applications in volatile processing environments, the unit is fully certified under ATEX, CNEX, and SIL3 safety integrity frameworks, ensuring maximum resistance to extreme electromagnetic interference.
Features
- Integrated Servo Module: We build the PCU directly into the unit, keeping all signal processing circuits completely shielded from your plant’s external environment.
- Signal Compatibility: Our boards support your multi-protocol analog input and output signals (4…20mA, 1…5 VDC, 1…10VDC) for direct integration with your DCS or PLC automation architecture.
- Our Available Upgrades: If your outdoor installations face severe day-to-night temperature fluctuations or high humidity (up to 90% RH), we highly recommend our optional 5W 10K internal space heater (dehumidification heater). This device maintains a stable micro-thermal environment, completely eliminating internal condensation to protect your electronics from short circuits.
Our Available Upgrades
For your high-humidity installations or plants handling severe thermal medium cycles, we offer an internal 5W 10K dehumidification space heater as an optional upgrade. It eliminates internal moisture accumulation, preventing electrochemical corrosion on your integrated modulating PCB.
Industrial Standards & Safety Compliance
We ensure our internal proportional tracking adheres to strict linear accuracy testing protocols. For your high-frequency modulating applications in volatile processing environments, we fully certify the unit under ATEX, CNEX, and SIL3 safety integrity frameworks, ensuring it resists extreme electromagnetic interference.
Performance Features
| Fuction: | On/off or modulating |
| Material | |
| Housing: | Aluminum alloy,epoxy powder coated |
| Gear: | Steel/aluminum bronze |
| Screws: | Stainless steel |
| Indicator Cover: | Polycarbonated |
| Shaft/Adaptor: | Alloy steel |
| Seal: | NBR |
| Lubrication: | Aluminum based grease |
| Technical Date | |
| Power Supply: | 24VDC,110VAC,220VAC |
| Motor: | Squirrel cage asynchronous motor |
| Limit Switch | SPDT,250VAC 10A,each for open and close positions |
| Rotation: | 90° (±10°)other rotation on request |
| Manual Operation: | Mechanical handle standard |
| Conduit Entry: | 2 x M18 |
| Operating Temp: | -20°C to + 70°C |
| Ambient Humidity: | Max.90%RH |
| Vibration Tested: | XYZ10g,0.2~34Hz,30 minutes |
| Mounting: | ISO5211 |
| Torque Output: | 30Nm to 1000Nm (2000Nm on request) |
| Self-locking device: | Self-locking by worm and worm gear |
Options Available
| Space Heater, 7 … 10W (110/220VAC)* |
| Stall Protection, internal overheating protection, open @ 120oC / close @ 97oC (± 5oC)* |
| Position Feedback Potentiometer (1K … 10K)* |
| Position Feedback Sensor with Current output (4 … 20mA)* |
| Proportional Control Unit for modulating control (input/output signal, 4 … 20mA, 1 … 5 VDC, 1 … 10VDC)* |
| Field control unit (Local control open/stop/close switch, Local/remote control switch)* |
| Power Failure Self Reset |
Standard & Technical datas
| Indicator | Dome Type( Option: LED Light Inside) | Enclosure | Waterproof Level IP67,NEMA4 and 6 |
| Ambient Temp | -20℃~+70℃ | Power Supply | AC110/220V 1PH±10% 50/60HZ.DC24V |
| Limit Switches | 2 open/close+dry contact 2 open/close | Travel Angle | 90º±5°(Extension up to 270º) |
| Manual Operation | Hex key (Option: Handwheel) | Self Locking | Provide self locking by worm gear |
| Space Heater | 5W(110/230VAC,24VDC) | Conduit entries | 2PF 1/2”(Option:M20x1.5,NPT1/2”) |
| Lubrication | Aluminum base grease(EP type) | External Coating | Dry powder, epoxy polyester |
| Surface Treatment | Anodizing | Material | Aluminum Alloy, Steel, Alloy Bronze |
Parts Materials

| NO. | Qty | Part name | NO. | Qty | Part name |
| 1 | 1 | Cross bolt (component) | 31 | 2 | Hexagonal nut |
| 2 | 1 | Dustproof end plug | 32 | 2 | Waterproof cable joint |
| 3 | 6 | Anti-break off hex type socket screw | 33 | 2 | O-ring |
| 4 | 1 | Oil seal | 34 | 2 | gasket |
| 5 | 1 | Electric fitting: front cap | 35 | 1 | Bearing |
| 6 | 1 | O-ring | 36 | 1 | Oil seal |
| 7 | 3 | Cross bolt (component) | 37 | 1 | Worm wheel |
| 8 | 3 | Cross bolt (component) | 38 | 1 | Electric fitting: inner cap |
| 9 | 1 | Electric fitting: speed-down case body | 39 | 1 | Bearing |
| 10 | 3 | Bearing | 40 | 4 | Cross bolt (component) |
| 11 | 3 | Electric fitting: reduction gear component | 41 | 1 | Stroke dog |
| 12 | 3 | Bearing | 42 | 1 | gasket |
| 13 | 1 | Electric fitting: speed-down case 1 | 43 | 1 | Stroke dog |
| 14 | 1 | Axis shield ring | 44 | 1 | gasket |
| 15 | 3 | Cross bolt (component) | 45 | 1 | gasket |
| 16 | 1 | Gear on worm | 46 | 1 | gasket |
| 17 | 1 | Insulating division board | 47 | 1 | Cross bolt (component) |
| 18 | 1 | Locknut | 48 | 1 | Dial |
| 19 | 1 | Electromotor rotor | 49 | 1 | Cross bolt |
| 20 | 1 | Bearing | 50 | 1 | Connecting terminal |
| 21 | 1 | Flat key | 51 | 2 | Cross bolt |
| 22 | 1 | Worm screw | 52 | 1 | Electric capacitor |
| 23 | 1 | Electromotor stator | 53 | 1 | Viewing glass |
| 24 | 1 | Bearing | 54 | 1 | O-ring |
| 25 | 1 | Bearing | 55 | 1 | Electric fitting: top cap |
| 26 | 1 | Insulating division board | 56 | 4 | Anti-break off hex type socket screw |
| 27 | 1 | Electric fitting: case body | 57 | 1 | O-ring |
| 28 | 1 | Allen wrench | 58 | 1 | Indication window hood |
| 29 | 2 | Limit bolt | 59 | 4 | Internal hexangular fillister head screw |
| 30 | 1 | handle holder |
Technical Parameter and Specifications
| Model | Max Output | Operating | Drive Shaft(mm) | Motor | Single-phsae | Weight | Flange | |||
| Torque (N.m) | Time 90°(Sec.) | (W) | rated current(A) | (kg) | Size | |||||
| 220VAC/24VDC | Square | Deep | Round | Deep | 220VAC/24VDC | |||||
| HEA005 | 50N.m | 30/15 | 11X11 | 15.5 | Ø12.6 | 26 | 10 | 0.25/2.2 | 4.1 | F05/F07 |
| 14X14 | 18 | |||||||||
| HEA008 | 80N.m | 30/15 | 11X11 | 15.5 | Ø15.78 | 26 | 10 | 0.25/2.2 | 4.1 | F05/F07 |
| 14X14 | 18 | |||||||||
| HEA010 | 100N.m | 30/15 | 14X14 | 18 | Ø15.78 | 28 | 15 | 0.35/3.5 | 5.1 | F05/F07 |
| 17X17 | 22.5 | Ø 18.95 | ||||||||
| HEA015 | 150N.m | 30/15 | 14X14 | 18 | Ø18.95 | 28 | 15 | 0.37/3.5 | 5.1 | F05/F07 |
| 17X17 | 22.5 | |||||||||
| HEA020 | 200N.m | 30/15 | 22X22 | 26 | Ø22.13 | 45 | 45 | 0.3/7.2 | 9.4 | F07/F10 |
| HEA040 | 400N.m | 30/15 | 22X22 | 26 | Ø28.48 | 45 | 60 | 0.33/7.2 | 9.4 | F07/F10 |
| HEA060 | 600N.m | 30/15 | 27X27 | 32.5 | Ø31.65 | 45 | 90 | 0.33/7.2 | 9.8 | F07/F10 |
| HEA080 | 800N.m | 40/20 | 27X27 | 32.5 | Ø31.65 | 45 | 180 | 0.47/11 | 15 | F10/F12 |
| HEA100 | 1000N.m | 40/20 | 27X27 | 32.5 | Ø31.65 | 45 | 180 | 0.47/11 | 15 | F10/F12 |
| HEA200 | 2000N.m | 45/22 | 27X27 | 32.5 | Ø31.65 | 45 | 180 | 1.5/15 | 15.3 | F10/F12 |
Purchase Guide
Required parameters to place an order
| Parameter | Options / notes |
| [Required] Model | HEA003 – HEA200 (same range as on/off)
Not sure? Contact us for selection support. |
| [Required] Voltage | 24VDC · 110VAC · 220VAC · 380VAC · 415VAC |
| [Required] Control signal input | 4–20mA or 0-10V |
| [Required] Feedback output type | 4–20mA or 0-10V continuous position output
Dry-contact open/close signals included as standard regardless. |
| [Required] Quantity |
Optional — add to order notes if needed
| Option | Notes |
| Modbus RTU (RS485) | Bus control and monitoring; analog feedback remains active alongside |
| Rotation angle | Default 90°; specify if 180° or 270° |
| Space heater | Specify voltage if required |
| Seal material | NBR (default) or EPDM |
| Low-temperature config | Specify minimum ambient temp if below -20°C |
| Custom color | Any RAL code; no MOQ |
FAQ About HEA Internal Modulating Type Quarter-Turn Electric Actuator
Q1: What control signal types are accepted?
A1: As a standard 4-20mA valve actuator, it accepts 4–20mA current signals and 0–10V voltage signals. Please specify your required signal type during the specification phase.
Q2: How does 4-20mA electric actuator work to determine valve position?
A2: How does 4-20mA electric actuator work? The analog signal maps linearly to the mechanical stroke: 4mA = fully closed (0%), 8mA = 25% open, 12mA = 50% open, 16mA = 75% open, 20mA = fully open (100%). This allows straightforward integration with process controllers.
Q3: What is the structural difference between a modulating vs on off electric actuator?
A3: When evaluating a modulating vs on off electric actuator, on-off units only drive the valve to 0% or 100% limits. A modulating electric actuator utilizes a positioning PCU board to maintain any intermediate stroke position, which is mandatory for applications like electric actuator water treatment modulating or precise electric actuator HVAC proportional control.
Q4: What position feedback outputs are available?
A4: A built-in potentiometer provides continuous position sensing. You can specify an electric actuator 4-20mA feedback output or a 0-10V voltage output, functioning alongside standard open/close dry-contact signals.
Q5: What is the rated service life of the internal gear train?
A5: The mechanical and electrical assemblies meet a strict electric actuator 30000 cycle life rating, making the unit structurally sound for continuous modulating duty in heavy industrial process control.
Q6: Does the actuator hold its position after a plant power failure?
A6: Yes. The internal worm gear acts as a modulating actuator self locking mechanism, keeping the valve mechanically locked in its last position when power is lost. A Power Failure Self Reset function can restore the control position upon power resumption.
Q7: What is the safe operating temperature range?
A7: Standard operating range is -20°C to +70°C. Low-temperature configurations are available down to -70°C for LNG, cold-climate pipelines, and refrigerated storage pipelines.
Q8: What specific safety and environmental certifications does it hold?
A8: Certification claims are strictly maintained to ATEX, CNEX, and SIL3 compliance frameworks to meet the core safety requirements of petrochemical and chemical processing industries.
Q9: Can it be ordered in custom RAL colors?
A9: Yes. Any RAL color can be specified with no minimum order quantity. Delivery will extend slightly beyond our standard 15 to 25-day lead time due to custom industrial paint mixing.